Description
Introducing the high-performance Mist-Fit 1050, a compact mist collector that leverages fiber bed filter technology for unparalleled air purification. Designed for high-pressure coolant and oil applications, this system efficiently returns oil to the CNC machine while maintaining a compact footprint for easy installation. Its modular design accommodates additional features as needed, ensuring a tailored solution for your workspace.
RFQ for additional accessories, mounts, filters, etc.
DOWNLOADS: Aeroex Digital Catalog MF-1050 Brochure
Technical Data:
- Coolant Filtration (Standard)
- Oil Filtration (Optional)
- Air Flow: 900-1100 cfm
- Machine Tool Enclosure: Up to 450 ft³
- Motor: 1.5 hp
- Voltage (Amps):
- 230/3/60 (2.7)
- 460/3/60 (1.6)
- Temperature (max) pH Limits: 125°F / 50°C, 5.8-9.8
- Weight: 98 lbs / 124 lbs with HEPA filter
- Dimensions: 20" x 20"
- Height:
- 28" base unit
- 33" with 95% HEPA filter
- 41" with 99.9% HEPA filter
- Inlet Connection: 8" ø
- Sound: 68 dB(A)
- Optional 4th Stage Filters:
- HEPA filter 95% @ 0.3 μm
- HEPA filter 99.9% @ 0.3 μm
Installs Quickly
Time is money, and in manufacturing that could make or break your reputation. AEROEX‘s sleek, modular mist collectors give you the professional edge with its quick install design. Fits most machine tools with little to no modification required
Easy to Use
AEROEX Mist Collectors are designed for hassle-free use, featuring easy-clean filters and straightforward operation to minimize downtime and keep your focus on the job. With their smart, user-friendly design, maintaining a clean shop environment is simpler than ever.
Clear the Air
Creating a safe and healthy work environment is crucial to the success of any machine shop. With AEROEX’s advanced multi-stage filtration technology, you're setting the standard for cleanliness and safety in your workspace, ensuring the wellbeing of your team and the durability of your machines.
Machine Tool Enclosure Sizing Guide
When determining the sizing of mist collectors, several factors come into play. As a rule of thumb, we suggest multiplying the machine enclosure volume by a factor of 2-6 depending on the mist level, with a factor of 2 suitable for large machines of 1000 cubic feet and above.
Condition | Multiplier (X) | Formula |
---|---|---|
Light Mist | 1 to 2 | L x W x H x Multiplier = Required CFM |
Moderate Mist | 3 to 4 | L x W x H x Multiplier = Required CFM |
Heavy Mist / Smoke | 4 to 6 | L x W x H x Multiplier = Required CFM |
Example: On a lathe with high-pressure coolant and an internal dimension of 5ft high X 6ft deep X 10ft long, the machine enclosure is 300 cubic feet—the calculation suggests an airflow requirement of approximately 900 CFM, when multiplied by a factor of 3.